首页 | 公司简介 | 数据恢复 | 成功案例 | 技术中心 | 客户服务 | 服务报价 | 联系我们 | 技术论坛  
 
  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  福 建 部: 0591-83300680
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

中国石油管理局-Oracle数据库恢
工商银行山东分行-AIX删除LV数
濮阳市地方税务局-CHKDSK后数据
台湾HD公司-FreeBSD Nas无法启
promise乔鼎硬盘阵列数据恢复成
IBM EXP300 磁盘阵列数据恢复成
NAS 8100无法挂载数据卷
Liteon-Dell 2850服务器数据恢

RAID损坏后 对数据的完整备份
LINUX FSCK数据出错灾难应急方
误删除、误格式化数据灾难应急
误GHOST、误一键恢复灾难应急方
磁盘未被格式化,是否格式化数据
raid磁盘阵列OFFLINE后的应急方
硬盘出现异响应急处理
您当前的位置:首页 >> 技术中心 >> 硬件故障恢复文栏 >> 正文

硬盘公司内部使用的英文缩写


IDNF ID Not Found (LBA error)
IDO Initial Drive Optimization
IDS1 Interconnect Data Server
IDT Initial Drive Test (SPT)
IEC International Electrical Committee 
IMP IBI Monitoring Program
IMRD Marketing requirement doc
ITR Issue Tracking Report
KFCI Kilo Flux Change per Inch
LBA Logical Block Address
LOB Line of business
LOH Labor overhead
LOETHE Low end of the high end
LT Log Tools
LTR Lock to Reference
LVD Low voltage differential (SCSI)
MCAL Magnetic Calibration Data
MD Middle Diameter
MDOS Multi-Tasking Drive Operating System
MMS Margin Monitoring System, a  type of data, contains drive processing status
MPU Micro-Processor Unit
MR Master revision
MRI Magneto Resistive head Instability
MSDR
MTBF Mean time between failures
MTTR Mean time to repair
Native Mode  Diagnostic mode
Nonoperating Drive power off
Nonrepeatable Error Data, ID, or framing error that doesn't recur when command is immediately repeated
NPI
NRRO Non Repeatable Run Out
NRZ Non return to zero
OD Outer Diameter
OEM Original equipment manufacturer
Operating Power on spin up, calibration complete (drive ready)
ORT Ongoing Reliability Test
OTP One Time Programmable
PAM
P list Primary defect list (IBI)
PD list Push Down list
PERCO PRML Enhanced Read Channel Optimization
PES Position Error Signal
PIO Processor input/output
PM Program manager
PMM Program manager meetings
POR Power On Reset
POST Power-on self test
PRD Product specifications/requirements document
PSG Personal storage group
QRD Quality requirement document
QVT Quality Verification Test
RBB list Relocated and bad block list
RCC Rack Controller Card (Xyratex)
RCF Reconfiguration
RDT
Recalibrate Heads moved to track 0
Recoverable Error Data, ID, or framing error is recovered when host retries are enabled
Repeatable Error Recurs on repeated command
RLL Run length limited
ROI Return on investment
RPD list Reserved cylinders push down list
RRC ROM Resident Code
RRO Repeatable Run Out
RSC Rescreen
RT list Relocated Track list
RVT Reliability verification test
RWC Read write current
RWCCS Read Write Channel Characterization Station
RWE Read Write error rate
SAM Error
SBC Serial Bus Controller
SBW Single Block Write
Scan Out Serial number mismatch check
SCT Sequence Control Table
SDC Smart Drive Controller, 12 SDC card inside one SPT, each SDC card controls five drives
SDH Select Drive and Head number register
SE
SECBITMAP Sector to Bitmap table
SFDM
SNR Signal to Noise Ratio
Spare Sector  Area At Inner Diameter of drive
SPC Statistical Process Control,  a type of data contains Servo Writer Status
SPT Single Plug Test or Sectors per Track
SRA Schedule risk assessment
SRE System reliability engineering
SRF Software Release Form
STW Servo Track Writer
TA Thermal Asperity (MR heads read bump friction heat as signal)
TAA  Track Average Amplitude
TARE Transparent Auto Relocation
TBMT Track Bit Map Table
TD list Track descriptor list
TE Test Engineering
TMR Track misregistration
TOC Time Offset Count (locates data following wedge)
TOL
TPI Tracks per inch
TPM Technical program metrics
Translate mode  Seen by end-user

本新闻共3页,当前在第2页  1  2  3  

上一篇:硬盘技术纵横谈--磁头篇
下一篇:硬盘技术纵横谈—马达和保护技术篇
返回首页 | 联系我们 | 关于我们 | 招聘信息 | 友情链接 | 网站地图 | 合作伙伴

版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-5880
中关村部:北京市海淀区中关村大街11号E世界A座832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室
京ICP备07502730